Power by county
Kinney, TX: data center power outlook
Kinney sits in the ERCOT market (Electric Reliability Council of Texas); what follows is the screening-grade grid picture for Kinney, Texas, drawn from public datasets. Counting from the mapped infrastructure, Kinney holds 5 mapped substations and reaches 138 kV. Kinney is covered by 7 retail service territories, including AEP TEXAS CENTRAL COMPANY, AEP TEXAS NORTH COMPANY, BANDERA ELECTRIC COOP, INC.
Grid position at a glance
- Serving utilities
- AEP TEXAS CENTRAL COMPANY, AEP TEXAS NORTH COMPANY, BANDERA ELECTRIC COOP, INC, MEDINA ELECTRIC COOP, INC, PEDERNALES ELECTRIC COOP, INC, RIO GRANDE ELECTRIC COOP, INC, SOUTHWEST TEXAS ELEC COOP, INC
- ISO / market
- ERCOT (Electric Reliability Council of Texas)
- Highest grid access
- 138 kV
- Substations in county
- 5
- Industrial retail rate
- 6.5¢/kWhState-level EIA-861 industrial average. The map colours by this, not by a per-county rate.
- Per-utility rates in county
- 5 of 7 serving utilities: 6.4 to 10.2¢/kWhLowest to highest industrial rate among the utilities serving this county (EIA-861 Sales to Ultimate Customers). A spread, not the county’s rate, and it covers only the serving utilities that report one.
- Interconnection queue
- 6 projects, 809 MW
- Proposed generation
- 467 MW planned or under constructionUnits filed with EIA as planned or under construction (Form EIA-860M). Declared intent from the federal inventory, not the interconnection queue and not guaranteed capacity.
- Grid carbon intensity
- 734 lb CO2/MWh
- Water withdrawals
- 3.9 Mgal/dAll uses, freshwater. Water already withdrawn locally, not water available for a new load.
- Construction labor near site
- 1,018 employed in construction within ~120 km (5 of 8 counties reporting)A large build needs hundreds of skilled construction workers on site for one to three years. A county with few of them within commuting range means bussing crews in, per diem, and housing, which is real cost and schedule risk. This counts people employed in construction within about a 120 km drive (BLS QCEW), summed across nearby counties. It is not labor known to be available: most are already committed to other projects, and no public data reveals who is free.
Grid conditions in Kinney
Below, Kinney in Texas is described from public data as a starting point for siting diligence. Kinney reaches 138 kV at its highest mapped voltage, a transmission class that can carry a substantial interconnection where capacity exists. Only 5 substations is mapped in Kinney, Texas, keeping interconnection points few.
Kinney falls inside the ERCOT market (Electric Reliability Council of Texas), which governs how its interconnection requests and capacity move. The rate for Kinney is the 6.5 cents per kWh state industrial average (EIA-861), the same figure the map colours by. Across Kinney, reported per-utility industrial rates cover 5 of 7 serving utilities: 6.4 to 10.2¢/kWh, offered only as context beneath the state figure.
Kinney has 6 interconnection-queue projects on record, totalling 808.9 MW of requested capacity. Kinney has 466.8 MW of planned or under-construction generation on file in EIA-860M. The balancing authority covering Kinney carries a grid carbon intensity of 734.003 lb CO2 per MWh in eGRID.
Reported freshwater withdrawals for all uses in Kinney are 3.87 million gallons per day in the USGS 2015 compilation, existing demand rather than water free for a new load. Around Kinney, some 1,018 people work in construction within about a 120 km commute (BLS QCEW), a measure of reach, not of available crews.
These numbers for Kinney are screening-grade context for the whole county, drawn from public data with the gaps left visible. Read the figures for Kinney, Texas together rather than one at a time: grid access matters less without substations near it, and a quiet queue reads differently inside an organized market than outside one. The next step for Kinney, Texas is an address-level interconnection study; the county figures here only narrow where to look. For Kinney, Texas, the source log below records where each figure comes from and when it was pulled, keeping the provenance visible.